CTDD1210D-S Series Fixed Input Isolated & Unregulated 1W Output, Single Output |
|
| Features |
| |
| Efficiency: To 80% |
| Temperature Range: -40°C to 85°C |
| Isolation: 1KVDC |
| Package: UL94-V0 |
| Miscellaneous: Single output voltage. No heatsink required. No external components required. Industry standard pinout. Small footprint. Custom service available. |
| Samples Available. |
| |
| Characteristics |
| |
| Short Circuit Protection: 1 second |
| Temperature Rise at Full Load: 25°C Max. 15°C Typ. |
| Cooling: Free air convection |
| Operating Temperature Range: -40°C to +85°C |
| Lead Temperature: 300°C (1.5mm from case for 10 seconds) |
| Storage Temperature Range: -55°C to +125°C |
| Storage Humidity Range: <95% |
| Case Material: Plastic (UL94-V0) |
| MTFB: >1,000,000 hours |
| |
| Part Number |
Vin Nom. (VDC) |
Input Range (VDC) |
Vout (VDC) |
Iout Max. (mA) |
Iout Min. (mA) |
Effi. Typ. (%) |
Request Samples & Quotes |
| CTDD1210D-0505S-1 |
5 |
4.5-5.5 |
5 |
200 |
20 |
78 |
Request |
| CTDD1210D-0509S-1 |
5 |
4.5-5.5 |
9 |
111 |
12 |
79 |
Request |
| CTDD1210D-0512S-1 |
5 |
4.5-5.5 |
12 |
83 |
9 |
80 |
Request |
| CTDD1210D-0515S-1 |
5 |
4.5-5.5 |
15 |
67 |
7 |
78 |
Request |
| CTDD1210D-1205S-1 |
12 |
10.8-13.2 |
5 |
200 |
20 |
78 |
Request |
| CTDD1210D-1209S-1 |
12 |
10.8-13.2 |
9 |
111 |
12 |
80 |
Request |
| CTDD1210D-1212S-1 |
12 |
10.8-13.2 |
12 |
83 |
9 |
81 |
Request |
| CTDD1210D-1215S-1 |
12 |
10.8-13.2 |
15 |
67 |
7 |
79 |
Request |
| CTDD1210D-2405S-1 |
24 |
21.6-26.4 |
5 |
200 |
20 |
79 |
Request |
| CTDD1210D-2409S-1 |
24 |
21.6-26.4 |
9 |
111 |
12 |
80 |
Request |
| CTDD1210D-2412S-1 |
24 |
21.6-26.4 |
12 |
83 |
9 |
81 |
Request |
| CTDD1210D-2415S-1 |
24 |
21.6-26.4 |
15 |
67 |
7 |
79 |
Request |
| |
| Item |
Test Condition |
Min |
Typ |
Max |
Units |
| Output Power |
- |
0.1 |
- |
1 |
W |
| Line Regulation |
For Vin change of 1% |
- |
- |
1.2 |
% |
| Load Regulation |
10% to 100% full load |
- |
- |
15 |
% |
| Output Voltage Accuracy |
See tolerance envelope graph |
- |
- |
- |
- |
| Temperature Drift |
100% full load |
- |
- |
0.03 |
%/°C |
| Output Ripple |
20Mhz Bandwidth |
- |
50 |
75 |
mVp-p |
| Switching Frequency |
Full load, nominal input |
100 |
150 |
200 |
KHz |
| Note: All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output unless otherwise specified. |
|
| Last Revised 12.14.04 |
|
|
|
|